Specifications

Characteristic

Transmitter

Display Receiver (with mains plug)

Dimensions

88mm (W) x 88mm (L) x 145mm (H) ±1mm

AUS/NZ: 50mm(W) x 59mm(D) x 199mm(H) ±3mm

Weight

143g

AUS: 71g

Housing Material

UV Stabilized Polypropylene

ABS

Operating temperature

-10°C to 60°C (Note 1)

-10°C to 60°C

Storage Temperature

-20°C to 60°C (Note 1)

-20°C to 60°C

Altitude range

<2Km above sea level

<2Km above sea level

Environmental Protection

IP67 – Outdoors

IP44 Indoors only

Radio frequency

NZ/AUS: 433.92 MHz FM

N/A

Radio output power

NZ/AUS: 5dBm +/- 2dBm

N/A

Receiver Sensitivity

N/A

-100dBm to -110dBm @ 0.001 BER

Ultrasonic range

>12cm to <3M (Note 2)

N/A

Ultrasonic signal diversion

30° (Note 3)

N/A

Material compatibility

(Note 4)

N/A

Power requirements

VARTA CR2430 3V Li-Manganese dioxide/Organic Electrolyte (fitted)

EU/UK/NZ/AUS: 230V AC 50-60Hz, 20mA

Battery life

> 5 Years

N/A

Humidity range

15% – 95%

15% – 95%

LCD Display

N/A

10 digit bar graph with icons


Accessories

Tank mounting options Drill 60mm hole and secure to tank using 2 x self tapping screwsScrews directly into 1 ¼”, 1 ½” or 2” BSP existing tank connection
Gasket (included) Material EPDM, Ø88mm x 4mm (H) ±1mmDistance between hole centres 75mm ±1mm
Screws (included) No.8 X 19mm Panhead Pozi-drive Stainless steel
Stabiliser support Optional extra to maintain horizontal alignment on tanks with angled top.

Note 1:
Storage and operation above 20°C may reduce battery life.
Note 2: Based on a measurement to a flat liquid target of size 30cm2. Option to extend range to 5m on some models.
Note 3: The maximum spatial diversion of the ultrasonic signal will be < 30° from the central axis of the transducer.
Note 4: Suitable for use in tanks for the storage of water diesel fuel, kerosene, AdBlue, gas oil types A2,C1,C2 and D as defined by BS2869
Left Right